Welcome on Sanitaria Triestina Store
  • AUDIOLAB PROFESSIONAL AUDIOMETER

AUDIOLAB PROFESSIONAL AUDIOMETER

Audiolab Audiometer

All the technology of a digital 2 channels clinical audiometer in only 250 g. You can perform audiometry test directly on your PC display, save on your database and print when necessary. Audiolab audiometer greatly simplifies masking operations. By selecting tracking function the device transmits to the collateral head phone the noise intensity according to the relative rule. The difference between tone and masking is already pre-set in the table and its values are freely modifiable by the operator.
Moreover the complete and innovative database system, due to real time preview of examination, allows immediate vision of the entire diagnostic process performed on the patient.You can easily overlap an existing audiogram to a previously selected one from the relative list. Pc not included.
Made in Italy.

Standards
Audiometric equipments EN 60645-1 (1994)
EN 60645 (1997) - EN 60645-4 (1995) - ANSI S3.6 (1996)
EN ISO 389 (1995) - EN ISO 389-2 (1994) ISO 389-3 (1994) - ISO 389-4 (1998) ISO 389-7 (1996)

Security
EN 60601 (1990) class II - type B
EMC - EN 60601-1-2 (2001)
  • Product code: 33605
  • Units: 1 pc.
  • Specifications:
    • Clinical audiometer two channels (EN 60645-1)
    Type 1 A-E (EN 60645-1 - EN 60645-2) - Type 2 A-E (ANSI S 3.6)
    Number of channels: 2, identical and indipendent
    • Output: AC R - AC L - AC R+L - BC R-L - FF R - FF L - FF R+L
    Masking contralateral with AC, BC, FF
    • Pure tone freq. AC: 125 - 8.000 Hz, BC: 250 - 8.000 Hz, FF: 125 - 8.000 Hz
    Intensity range (1.000 Hz) - 10 + 120 dB Hl

    • Maximum output level

    PURE TONE 1,000 Hz

    - Transducer TDH49 ER3A B71 FF
    - Db HL 120 115 75 100
    - NBM 95 95 - 95

    • Speech Audiometry

    - Transducer TDH49 ER3A B71 FF
    - Db HL 100 100 - 100
    - NBM 95 95 - 95

    • Vocal material

    - List of the words installed into internal flash memory
    - CH1 - CH2 independent inputs, CD1, CD2 two separate VU-Meters,masking noise SM and WM.

    • Signal mode: Normal ON - Normal OFF
    • Continuos - pulsed
    • Warble - frequency modulated ± 5% rate 5 Hz
    • ABLB, SISI with increment 1-2-3-4-5 dB, DECAY TEST, BEKESY (only 33605)
    • PAT RESPONSE
    • TALK - BACK
    • TALK - FORWARD
    • Digital output for control Peep-Show

    • Accuracy
    - Resolution 16 Bit
    - Precision ± 50 ppm
    - Stability ± 100 ppm
    - Distorsion < 1%
    - Ratio signal/noise > 100dB
    - Power supply: USB port

    • PC system requirements Microsoft Windows XP, Vista Made in Italy