Welcome on Sanitaria Triestina Store
  • DIATERMO MB 200 FLASH - mono-bipolar

DIATERMO MB 200 FLASH - mono-bipolar

MB FLASH are a High Frequency Radio Surgical equipment suitable for precision monopolar and bipolar surgery and micro-surgery without tissue alterations. MB FLASH allow surgical treatments with programmable timer operations up to milliseconds or with traditional mode. MB FLASH allow pure CUT, cut-coagulation BLEND, incision with reduced production of eschar ENHANCED, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG and BIPOLAR coagulation ABLATION. Digital reading of delivered power and the surveillance through microcontroller of the operational functions, assure absolute reliability of the working conditions. MB FLASH allow a highly professional surgery through ergonomic and safety features. Connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. Possibility to control the output functions and the delivery of output power by handle, allows surgical operation without diverting attention from the surgical field.

Features:
- Patient to plate contact control
- Split return electrode use allowed
- Minimally invasive surgical treatment allowed
- Monopolar and Bipolar indipendent output
- Auto Start/Stop in Bipolar Coag
- Working condition planning
- Power delivery by pedal and/or handle
- Digital regulation and indication of the output power
- Sound level control
- Adjustable power increment
- RF power pulse emission time setting
- RF power pulse interval setting

- OUTPATIENT SURGERY
- DERMATOLOGY
- VASCULAR SURGERY
- GYNECOLOGY
- DENTAL
- OTORHINOLARYNGOLOGY
- PEDIATRIC SURGERY
- FIRST AID
- PLASTIC SURGERY
- ENDOSCOPY
- OPHTHALMOLOGY
- NEUROSURGERY
- PODIATRY
- PNEUMOLOGY
- UROLOGY
- VETERINARY

Catalog
  • Product code: 30633
  • Units: 1 pc.
  • Specifications:
    • Max output power CUT: 200 W-250 O
    • Max output power BLEND: 120 W-200 O
    • Max output power ENHANCED: 120 W-250 O
    • Max output power FORCED COAG: 150 W-150 O
    • Max output power SOFT COAG: 90 W-100 O
    • Max output power BIPOLAR COAG: 80 W-50 O
    • Working frequency: 600 KHz
    • RF power pulse emission time: 10 ms - 30 sec.
    • RF power pulse interval: 1 - 9
    • Patient circuit: F
    • Selectable input voltage: 115 - 230 Vac
    • Mains frequency: 50 - 60 Hz
    • Electrical input power: 350 VA
    • Size WxHxD mm: 370 x 144 x 319
    • Weight: 6 kg
    • Controls: Patient/Plate circuit monitoring, Output power monitoring, Self check control
    • Safety: EN60601-1, EN60601-1-2, EN60601-2-2, Electrical Class: I CF, MDD 93/42/EC Class: II b