DIATERMO MB202 - mono-bipolar - 200 Watt
DIATERMO MB 200 and MB 202 are HF electrosurgical units suitable to effect middle monopolar or bipolar electrosurgery. The available waveforms and peak voltage value, as well as the accurate HF leakage current operation for polypectomy, TURP, intrauterine resections, endometriosis excision, etc. The units allow the accurate preset of the output power with as low as 1 Watt resolution and to perform coagulation with high crest factor current, to get an elevated thermal effect, as well as with low voltage low crest factor current, to get coagulation in absence of carbonization. Ten different programs related to ten different operative conditions could be stored and easily recalled by the surgeon. The use of either split or normal neutral plates are allowed. A special electronic circuit (Skin Plate Electronic Control) continuously warns the plate to patient contact safety and unwanted short circuit in the connecting cable. An over time warning (OVT) is provided to prevent excessive heating of the tissue around the surgical target due to too long current delivery time. DIATERMO MB 202, furthermore, can be used with current delivery time equal to that of actuation of the output power switch as well as with preset current delivery time in the range from 1 ms up to 999 ms.
The output pulse can be automatically repeated 1 to 250 times. The presetting of the current delivery time is propre for collecting of bioptic samples and for microsurgical dermatologic operationy like treatment of telangiectasias, spider nevus, angiomas, efc. Bipolar cable and forceps are not included in standard specifications.
The output pulse can be automatically repeated 1 to 250 times. The presetting of the current delivery time is propre for collecting of bioptic samples and for microsurgical dermatologic operationy like treatment of telangiectasias, spider nevus, angiomas, efc. Bipolar cable and forceps are not included in standard specifications.
- Product code: 30546
- Units: 1 pc.
- Specifications:
• Minimum preselectable power: 0_x000D_
• Level step digital: 1_x000D_
• Maximum output power CUT (W): 200 - 250 ohm_x000D_
• Maximum output power CUT 90% (W): 200 - 250 ohm_x000D_
• Maximum output power CUT 80% (W): 200 - 250 ohm_x000D_
• Maximum output power CUT 70% (W): 200 - 250 ohm_x000D_
• Maximum output power BLEND (W): 120 - 200 ohm_x000D_
• Maximum output power COAG FORCED (W): 150 - 150 ohm_x000D_
• Maximum output power COAG SOFT (W): 100 - 100 ohm_x000D_
• Maximum output power BIPOLAR (W): 100 – 100 ohm_x000D_
• Maximum output power BIPOLAR COAG (W): -_x000D_
• Maximum output power BIPOLAR CUT (W): -_x000D_
• Crest Factor CUT: 1.5_x000D_
• Crest Factor CUT 90%: 1.6_x000D_
• Crest Factor CUT 80%: 1.7_x000D_
• Crest Factor CUT 70%: 1.8_x000D_
• Crest Factor BLEND: 2.1_x000D_
• Crest Factor COAG FORCED: 2.0_x000D_
• Crest Factor COAG SOFT: 1.7_x000D_
• Crest Factor BIPOLAR: 1.5_x000D_
• Crest Factor BIPOLAR CUT (W): -_x000D_
• Working frequency: 600 kHz_x000D_
• Weight: 8 Kg_x000D_
• Size LxHxD: 360 x 150 x 265 mm_x000D_
• Selectable mains power(Vac): 115 -230_x000D_
• Mains frequency (Hz): 50-60_x000D_
• Fuses 230Vac (5x20) TIMED: 2x 3.15A_x000D_
• Fuses 115Vac (5x20) TIMED: 2x 6.3A_x000D_
• Power accuracy output warning system _x000D_
• Split or not split patient plate allowed _x000D_
• Timed delivery repetition: 1-999 ms_x000D_
• Electrical Class (EN60601 - 1): I CF_x000D_
• MDD 93/42/EEC Class: II b_x000D_
• Patient circuit: F_x000D_
• Duty cycle (action/pause) in seconds: 10/30 _x000D_