MINDRAY PM-60 PULSE OXIMETER
PM-60 is a miniature, lightweight device capable of spotcheck and continuous monitoring of SpO2 and pulse rate.
Spot Check Mode
- Auto-standby and power off during the idle status
- Auto-increase the patients IDs
- Non-alarm setting for “sensor off“ occasion 1-99 IDs for maximum 4000 sets of measurements
Continuous monitoring mode
- Regular alarm handing
- Enable to input patient ID manually
- View SpO2 waveform for maximum 96 hour trend
Other features
- Suitable for adult and pediatrics patients
- High resolution 2.4" colour LCD display
- Adjustable visual and audible alarms
- Real-time data transfer by infrared technology
- Choose between Litium-ion or AA alkaline batteries (for up to 36 hours continuous working) depending on your run-time needs
- Protective cover perfect for portable monitoring needs
- Supplied with adult reusable sensor
Catalog
Spot Check Mode
- Auto-standby and power off during the idle status
- Auto-increase the patients IDs
- Non-alarm setting for “sensor off“ occasion 1-99 IDs for maximum 4000 sets of measurements
Continuous monitoring mode
- Regular alarm handing
- Enable to input patient ID manually
- View SpO2 waveform for maximum 96 hour trend
Other features
- Suitable for adult and pediatrics patients
- High resolution 2.4" colour LCD display
- Adjustable visual and audible alarms
- Real-time data transfer by infrared technology
- Choose between Litium-ion or AA alkaline batteries (for up to 36 hours continuous working) depending on your run-time needs
- Protective cover perfect for portable monitoring needs
- Supplied with adult reusable sensor
Catalog
- Product code: 35060
- Units: 1 pc.
- Specifications:
• Display: 2.4“ color TFT Resolution: 320 x 240
• Multi dispays selectable: standard or waveform screen
• Trace: 1 plethysmogram waveform
• Indicator: alarm indicator light, power indicator light, pulse tone, alarm sound, button tones
• Interface: dual-purpose socket for connecting SpO2 sensor and communication cable IR interface: infrared link allows downloading realtime patient data to computer
• DC power interface: Charger stand for Li-ion battery
• DC power requirements: input voltage 5V DC Power 1.2A
• Battery:
- Li-ion battery 24 hours continuous working
- 3xAA batteries 36 hours continuous working
• Trend memory:
- Monitoring mode: Resolution: 2s - Maximum time: 96 h
- Spot-check mode: Review of up to 4000 data, measure up to 99 patients
• Alarm: user adjustable high and low limits 3-level audible and visual alarm
SpO2
• Measurement range: 0~100% ±2% (70~100%)
• Resolution: 1% Alarm range: 50~100%
• Refreshing rate: 1 s
• Averaging time:
- 7 s (sensitivity set HIGH)
- 9 s (sensitivity set MED)
- 11 s (sensitivity set LOW)
Pulse rate
• Range: 18~300 bpm (±3 bpm non-motion)
(±5 bpm motion)
Alarm range: 18~300 bpm
• Resolution: 1 bpm
• Refreshing rate: 1 s
• Averaging time: same as SpO2
• Type of protection: Class II with internal electric power supply
• Degree of protection: BF (defibrillation proof)
• Protection against ingress of liquid: IPX 2