FC1400 SINGLE FOETAL MONITOR
Superior data display
- 320 x 240 color LCD viewer (4.3 inch)
- FHR and automatic fetal movement detection
- 12 hours of memory capacity
- Recommended after week 30
Extreme data accuracy and access
- High-accuracy and wide detection area
- Easy on-screen scrolling function
- Endurable watertight probes, 1 MHz
Printout
- CTG analysis printing
- Both standard and A4 size paper usable
- Normal fax paper usable
- High speed printout (50 cm/min)
Other advantages
- Wireless central monitoring up to 8 beds (Option)
- PC compatible
- Internal battery lasting 2-hours (Option)
- Power adapter 100-240 V, 50-60 Hz
Catalog
- 320 x 240 color LCD viewer (4.3 inch)
- FHR and automatic fetal movement detection
- 12 hours of memory capacity
- Recommended after week 30
Extreme data accuracy and access
- High-accuracy and wide detection area
- Easy on-screen scrolling function
- Endurable watertight probes, 1 MHz
Printout
- CTG analysis printing
- Both standard and A4 size paper usable
- Normal fax paper usable
- High speed printout (50 cm/min)
Other advantages
- Wireless central monitoring up to 8 beds (Option)
- PC compatible
- Internal battery lasting 2-hours (Option)
- Power adapter 100-240 V, 50-60 Hz
Catalog
- Product code: 29530
- Units: 1 pc.
- Specifications:
• Doppler:
- Pulsed Doppler
- Ultrasound frequency: 1.0 MHz
- Intensity: <10mW/cm2
- FHR range: 50-240 bpm (± 1 bpm)
• Fetal movement:
- Detection source: Ultrasound pulsed doppler
• UC:
- Frequency response: DC 0.5 Hz
- Reference (zero) control
- Measurement range: 0~99 units
• Printer:
- Thermal array type
- Print speed: 1, 2, 3 cm/min
- Paper feeding function
• Display:
- 320 x 240 Colour LCD
• Indicators:
- Heart rhythm with signal quality
- Alarm, printing on/off state
- AC power
• Set-up:
- Alarm upper/low limit value
- Record speed, paper grid, Fetal
- Movement On/Off, Time/Date, Print contrast, Auto print period
• Power:
- Input: AC 100-240V (50/60 Hz)
- Output: DC 18V, 2.5A
- Consumption: 80W
• Dimensions:
- 296(W)x 305.5(H) x 92.5(D)mm
- Weight: approx 3.2 kg
• External link:
- RS-232C: Program Download
ANALYSIS FUNCTION
- Period: test period
- Average baseline FHR (bpm)
- Number of UC (frequency / h)
- Number of acceleration (frequency / h)
- Number of deceleration (frequency / h)
- Late DEC: number of late deceleration
- Early DEC: number of early deceleration
- Variable DEC: number of variable deceleration
- TACHY: moderate (>160 bpm): period of that FHR is between 160~190 (minutes)
- TACHY: severe (>190 bpm): period of that FHR is over 190 (minutes)
- BRADY: moderate (<110 bpm): period of that FHR is between 90~110 (minutes)
- BRADY: severe (<90 bpm): period of that FHR is lower than 90 (minutes)